TX7008R Integrated Fire Alarm Panel
40+ years
Experience
400+ Patents
Full sets LPCB
1,000,000+
projects worldwide
Global on site
after sale service
7x24h
response service
Overview: Integrated Fire Alarm Panel
The TX7008R Integrated Fire Alarm Panel integrated fire alarm panel, fire telephone system, fire broadcast system.
Feature and Benefits:
•EN54-2 & EN54-4 Compliance
•Using advance microprocessor technology with Large memory capacity
•Enhance user interface combining LCD Touch screen and keypad access
•Support real time visual algorithm
•Enhance false alarm prevention
•Keypad and PC programming
•Multiple interface protocol USB/Ethernet/Can Bus/Serial/RS485/Fiber Optic
•Support Loop Powered devices for extra saving on cable cost
•Built-In Printer and 160 LED Zones Indicators
Menu
Commissioning Advantage
•Auto Enrolling of Devices
•Loop Mapping with colour coding status
•Monitor device mismatch and dual address conflict
•Command Builder to create requirements for fire event scenario
•With Loop protection against power surge
•One-man test with On/Off sounder
•Programming Protection
System Capacity
•Support 254 Devices/One loop (2,032 ideal)
•Network up to 512 Node
•Zones up to 3000
•Groups up to 3000
Technical Specification
| Input Voltage | 230VAC +10%-15%,50Hz |
| Network Panel to panel | 512 Panels- Single Ring[Ideal] |
| Communication Card | CanBus |
| Protocol/Addressing | T&A, Value range from 1 to 254 |
| No. of Loop | 10 Loop Standalone |
| Protection | Built-in 4kV Surge protection |
| Programmable Relays | 4 circuits: Normally Open/Close |
| Programmable Input | 1 Circuit: Power limited 24VDC |
| Programmable Aux Power | Limited 19-28VDC |
| Fixed Outputs | 2 Circuits:Power limited 18-28VDC |
| Indicator | 24 LED Status/ 160 Zone Indicators |
| Display | 7”TFT Touch Screen |
| Keypad | 5 Brigade buttons and Programming Keypad |
| Material/Color | Flat sheet Metal /Black |
| Dimension/HWD | 1715 x 550 x 480mm |
| Temperature | -5℃~+40℃ |
| Humidity | 0 to 95% Relative Humidity, Non condensing |
| Input Voltage | 230VAC +10%-15%,50Hz | Humidity | 0 to 95% Relative Humidity, Non condensing |
| Network Panel to panel | 512 Panels- Single Ring[Ideal] | Temperature | -5℃~+40℃ |
| Communication Card | CanBus | Dimension/HWD | 1715 x 550 x 480mm |
| Protocol/Addressing | T&A, Value range from 1 to 254 | Material/Color | Flat sheet Metal /Black |
| No. of Loop | 10 Loop Standalone | Keypad | 5 Brigade buttons and Programming Keypad |
| Protection | Built-in 4kV Surge protection | Display | 7”TFT Touch Screen |
| Programmable Relays | 4 circuits: Normally Open/Close | Indicator | 24 LED Status/ 160 Zone Indicators |
| Programmable Input | 1 Circuit: Power limited 24VDC | Fixed Outputs | 2 Circuits:Power limited 18-28VDC |
| Programmable Aux Power | Limited 19-28VDC |
How to silence and reset a fire alarm panel?

This is a complex process that requires professional assistance, but a brief overview is provided below:
1, Make sure all addressable devices are encoded with a unique number, you can encode them with the TX7932 Handheld Programmer.
2, Connect the loop with the fire alarm panel
3, Set the panel to commissioning mode and set the passcode
4, Upload the pre-configured database from TX7810 programming software through a computer to the fire alarm control panel.
5, Test the system
For detailed instructions, don’t hesitate to get in touch with our customer service team.
TX7 Serials Fire Alarm Panels
Tandatech manufacture various fire protection products. Based on different project requirements, Tanda Technology has a variety of fire alarm panels to adapt. All annunciator fire alarm system panels meet the EN54 standard. Among them, TX7004 is the first fire protection product in China to obtain LPCB certification. In addition to the functions of ordinary fire alarm system panels, TX7008R integrates a broadcast system and a telephone system.

TX7004 Fire Alarm Control Panel

TX7008R Integrated Fire Alarm Panel

TX7008 Addressable Fire Alarm Control Panel

TX7002 Fire Alarm Control Panel
TX7 Serials Addressable Fire Alarm Panels
A Fire Alarm System is powerful that not only requires a core control panel like the LPCB CE certified TX7004 FACP (Fire Alarm Control Panel), but also needs to be paired with other detectors, modules, and appropriate configurations based on the project’s scale to maximize its effectiveness to realize 1 loop fire alarm panel, 2 loop addressable fire alarm panel, 4 loop addressable fire alarm panel, up to multiples 256 loops fire alarm system.


TX7988 Duct Probe Smoke Detector

TX7810 Fire Alarm Configuration Tool

TX7320 Addressable Fire Alarm Sounder

TX7301 Addressable Fire Alarm Sounder Strobe

TX7300 Addressable Fire Alarm Sounder Strobe

TX7223 Addressable 12in/2out Fire Alarm Module

TX7221 Multi Channel I/O Fire Alarm Module

TX7222 Addressable Zone Monitor and Sounder Circuit Module

TX7240 Loop Relay Module

TX7230 Analogue Addressable Isolator Module

TX7211 Addressable Sounder Circuit Module

TX7220 Addressable Dual Input-output Module

TX7210 Addressable Single Input-output Module

TX7201 Addressable Zone Monitor Module

TX7200 Addressable Input Module

TX7153 Fire Hydrant Start Button

TX7142 Intelligent Manual Call Point

TX7302 Addressable Sound Light Strobe Base

TX7322 Addressable Fire Alarm Sounder Base

TX7232 Base Mount Short Circuit Isolator

TX7980 Fire Alarm Universal Base

TX7140 Addressable Manual Call Point

TX7120 Intelligent Multi-sensor Fire Detector

TX7110 Intelligent Heat Detector

TX7100 Smoke Detector

TX7330 LCD Repeater Panel

TX7932 Handheld Programmer

TX7812 Graphic Monitor Center Software

TX7008R Integrated Fire Alarm Panel