TX7100 Intelligent Smoke Detector
40+ years
Experience
400+ Patents
Full sets LPCB
1,000,000+
projects worldwide
Global on site
after sale service
7x24h
response service
Overview: Intelligent Smoke Detector
The TX7100 intelligent Addressable Optical Smoke Detector is the ideal device for most applications due to its linear response to a wide variety of smoke patterns, The unit is manufactured to meet the sensitivity requirement of EN 54 part 7, European Standard. The unit is aesthetically pleasing with an unobtrusive design that will complement modern building designs. The unit incorporates an intelligent processor that provides an Algorithm map, an inbuilt A/D converter, Drift compensation, and Self-Diagnosis and History log.
Feature and Benefits
1, Analog transmission & digital addressing
2, Provides real-time status data to the alarm control panel
3, Intelligent linear compensation algorithm
4, 360° visible indicator light
5, On-site adjustable device parameters
6, Dust-proof cover
7, Remote indicator output
8, Complies with EN54-7 standard
Technical Specification
Approvals: LPCB / CE-CPR
Input Voltage: 24VDC [16V to 28V]
Current Consumption: Standby 0.6mA,Alarm:4mA
Protocol/Addressing: T&A, Value range from 1 to 254
Sensitivity: As per stipulated standard
Indicator: Single LED / 360-degree Visual
Material / Color: ABS/White Glossy finishing
Dimension / Height: Diameter 99.7 mm / 57 mm
Weight: 145g (with Base), 90g (without Base)
Operating Temperature: -10°C to +50°C
Humidity: 0 to 95% RH, Non condensing
Menu
TX7100 Intelligent Smoke Detector Coverage

The coverage range of TX7100 smoke detectors presents two gradients, mainly depending on the installation height:
When the installation height is not higher than 6 meters, the coverage radius is 5.8 meters, and the area is about 60 square meters;
when the height is between 6 meters and 12 meters, the coverage radius is 6.7 meters, and the area is about 80 square meters.
When the height of the building is higher than 12 meters, it is recommended to choose TX7130 infrared beam smoke detector, which is summarized in the following table:
How Do Smoke Detectors Work?
TX7100 smoke detector secure and speedy communication through the on-board processor enables the detector to make its own decision, resulting in greater automation.
In the event of fire, the integral microprocessor analyzes the signal according to factors such as signal strength and rate of increase, then confirms these patterns with the pre-programmed fire scenarios and smoke patterns, for a faster and safer response.
Once it is confirmed, the LED indicates the sensor status and a parallel communication signal to the control panel. The TX7100 detector is compatible with the TX7004 analogue intelligent fire alarm control panel, produced by a single manufacturer T&A, to avoid addressable communication compatibility problems.
Optical Smoke Detector Application
The TX7100 Optical Smoke Detector is intelligent, it’s Applicable Locations – Hotels, office buildings, shopping malls, residential communities, entertainment venues, data centers, archives, and other public areas
Non-Applicable Locations – Areas with normal presence of dust, steam, oil mist, or water vapor, as well as high-altitude regions

TX7 Serials Addressable Fire Alarm Panels System
A Fire Alarm System is powerful that not only requires a core control panel like the LPCB CE certified TX7004 FACP (Fire Alarm Control Panel), but also needs to be paired with other detectors, modules, and appropriate configurations based on the project’s scale to maximize its effectiveness.


TX7988 Duct Probe Smoke Detector

TX7810 Fire Alarm Configuration Tool

TX7320 Addressable Fire Alarm Sounder

TX7301 Addressable Fire Alarm Sounder Strobe

TX7300 Addressable Fire Alarm Sounder Strobe

TX7223 Addressable 12in/2out Fire Alarm Module

TX7221 Multi Channel I/O Fire Alarm Module

TX7222 Addressable Zone Monitor and Sounder Circuit Module

TX7240 Loop Relay Module

TX7230 Analogue Addressable Isolator Module

TX7211 Addressable Sounder Circuit Module

TX7220 Addressable Dual Input-output Module

TX7210 Addressable Single Input-output Module

TX7201 Addressable Zone Monitor Module

TX7200 Addressable Input Module

TX7153 Fire Hydrant Start Button

TX7142 Intelligent Manual Call Point

TX7302 Addressable Sound Light Strobe Base

TX7322 Addressable Fire Alarm Sounder Base

TX7232 Base Mount Short Circuit Isolator

TX7980 Fire Alarm Universal Base

TX7140 Addressable Manual Call Point

TX7120 Intelligent Multi-sensor Fire Detector

TX7110 Intelligent Heat Detector

TX7100 Smoke Detector

TX7330 LCD Repeater Panel

TX7932 Handheld Programmer

TX7812 Graphic Monitor Center Software

TX7008R Integrated Fire Alarm Panel

TX7008 Addressable Fire Alarm Control Panel
Smoke Detector FAQ
How to test smoke detector?
Detector Configuration, includ detector addressing, set LED On/Off and read configuration, you can program the detector with the TX7932 programmer.
Do smoke detectors detect carbon monoxide?
No, this TX7100 can not detect somke and carbon monoxide at the same time, but the model TX7120 smoke and gas detector can do these.
Where to install smoke detectors?
Due to the coverage space, it is recommended that TX7100 is installed under 8 meters high, while the TX7130 beam smoke detector is installed above 8 meters high.